Description | Output a signal defined by the Duty Cycle, Base Frequency, and Input. Enable can be used to enable or disable the output Volts. Duty Cycle is the percentage of one period of the waveform that the signal is HIGH. Base Frequency is the frequency of the signal. |
Availability |
|
savvy-SFD Graphic | |
Graphic with Parameters |
Input |
Input, Read-write, Analog (signed 16-bit integer) 10.0 % to 327.7 % |
Base Frequency |
Input, Read-write, Analog (signed 16-bit integer) 0.03 kHz to 100.00 kHz Note that changing the Base Frequency may cause discontinuities (glitches) in the output. |
Duty Cycle |
Input, Read-write, Analog (signed 16-bit integer) 0.0 % to 100.0 % |
Enable |
Input, Read-write, Boolean (signed 16-bit integer) 0 = Disabled 1 = Enabled |