Winder
Torque Compensator
Description For use with Diameter Calculator function block. Must have a Diameter Calculator function block placed in the SFD and set the Diameter Calculator parameter in the Torque Compensator to the placed function block.
Availability
  • Available only in the dw1xx series products
  • Requires library: Winder Control (option -06)
  • Firmware versions 0x100C and later
savvy-SFD Graphic torqueComp
Graphic with Parameters torqueComp

Parameters

Diameter Calculator Internal Parameter, Read-write, Function Block Association (signed 16-bit integer)
Tension Demand Input, Read-write, Analog (signed 16-bit integer)
-100.00 % to 100.00 %
Tension Scaler Input, Read-write, Analog (signed 16-bit integer)
-327.67 % to 327.67 %
Friction Monitor Internal Parameter, Read-only, Analog (signed 16-bit integer)
-327.67 % to 327.67 %
Torque Trim Input, Read-write, Analog (signed 16-bit integer)
-150.00 % to 150.00 %
Torque Demand Internal Parameter, Read-only, Analog (signed 16-bit integer)
-327.67 % to 327.67 %
Tension Enable Input, Read-write, Boolean (signed 16-bit integer)
0 = Inactive
1 = Enabled
Under/Over Select Input, Read-write, Boolean (signed 16-bit integer)
0 = Underwind
1 = Overwind
Inertia Monitor Internal Parameter, Read-only, Analog (signed 16-bit integer)
-327.67 % to 327.67 %
External Torque Input Input, Read-write, Analog (signed 16-bit integer)
-150.00 % to 150.00 %
External Torque Enable Input, Read-write, Boolean (signed 16-bit integer)
0 = Inactive
1 = Enabled
Nominal Torque Input, Read-write, Analog (signed 16-bit integer)
0.00 % to 150.00 %
Positive Torque Demand Output, Read-only, Analog (signed 16-bit integer)
0.00 % to 327.67 %
Negative Torque Demand Output, Read-only, Analog (signed 16-bit integer)
-327.67 % to 0.00 %
Dynamic Friction Internal Parameter, Read-write, Analog (signed 16-bit integer)
-327.67 % to 327.67 %
Static Friction Internal Parameter, Read-write, Analog (signed 16-bit integer)
-327.67 % to 327.67 %
Stiction Internal Parameter, Read-write, Analog (signed 16-bit integer)
-327.67 % to 327.67 %
Stiction Reel Speed Threshold Internal Parameter, Read-write, Analog (signed 16-bit integer)
0.00 % to 10.00 %
Stiction Web Speed Threshold Internal Parameter, Read-write, Analog (signed 16-bit integer)
0.00 % to 10.00 %
Variable Inertia Internal Parameter, Read-write, Analog (signed 16-bit integer)
-327.67 % to 327.67 %
Material Width Internal Parameter, Read-write, Analog (signed 16-bit integer)
0.00 % to 327.67 %
Fixed Inertia Internal Parameter, Read-write, Analog (signed 16-bit integer)
-327.67 % to 327.67 %
Acceleration Time Internal Parameter, Read-write, Analog (signed 16-bit integer)
-3000.0 s to 3000.0 s

Negative values are allowed to change the sign of the acceleration.
0 = Disable
Acceleration Filter Time Constant Internal Parameter, Read-write, Analog (signed 16-bit integer)
0.00 s to 300.00 s
0 = Off
Acceleration Monitor Internal Parameter, Read-only, Set to default on hard initialization, Analog (signed 16-bit integer)
-327.67 % to 327.67 %
External Acceleration Input Internal Parameter, Read-write, Analog (signed 16-bit integer)
-105.00 % to 105.00 %
Friction Sign Input, Read-write, Boolean (signed 16-bit integer)
0 = Positive
1 = Negative