| Description | (description coming soon) |
| Availability |
|
| savvy-SFD Graphic | ![]() |
| Graphic with Parameters | ![]() |
| Reset |
Input, Read-write, Boolean (signed 16-bit integer) 0 = Inactive 1 = Reset |
| State Persistence |
Internal Parameter, Read-write, Boolean (signed 16-bit integer) 0 = Reset on power-up 1 = Persistent |
| Logic Input 1 |
Input, Read-write, Boolean (signed 16-bit integer) 0 = Low 1 = High |
| Logic Input 2 |
Input, Read-write, Boolean (signed 16-bit integer) 0 = Low 1 = High |
| Logic Input 3 |
Input, Read-write, Boolean (signed 16-bit integer) 0 = Low 1 = High |
| Logic Input 4 |
Input, Read-write, Boolean (signed 16-bit integer) 0 = Low 1 = High |
| Logic Input 5 |
Input, Read-write, Boolean (signed 16-bit integer) 0 = Low 1 = High |
| Logic Input 6 |
Input, Read-write, Boolean (signed 16-bit integer) 0 = Low 1 = High |
| Logic Input 7 |
Input, Read-write, Boolean (signed 16-bit integer) 0 = Low 1 = High |
| Parameter 1 |
Input, Read-write, Analog (signed 16-bit integer) -327.67 % to 327.67 % |
| Parameter 2 |
Input, Read-write, Analog (signed 16-bit integer) -327.67 % to 327.67 % |
| Parameter 3 |
Input, Read-write, Analog (signed 16-bit integer) -327.67 % to 327.67 % |
| Parameter 4 |
Input, Read-write, Analog (signed 16-bit integer) -327.67 % to 327.67 % |
| Parameter 5 |
Input, Read-write, Analog (signed 16-bit integer) -327.67 % to 327.67 % |
| Parameter 6 |
Input, Read-write, Analog (signed 16-bit integer) -327.67 % to 327.67 % |
| Parameter 7 |
Input, Read-write, Analog (signed 16-bit integer) -327.67 % to 327.67 % |
| Counter 1 |
Internal Parameter, Read-only, Analog (unsigned 16-bit integer) 0 to 65535 |
| Counter 2 |
Internal Parameter, Read-only, Analog (unsigned 16-bit integer) 0 to 65535 |
| Counter 3 |
Internal Parameter, Read-only, Analog (unsigned 16-bit integer) 0 to 65535 |
| Counter 4 |
Internal Parameter, Read-only, Analog (unsigned 16-bit integer) 0 to 65535 |
| Aux State |
Output, Read-only, Hexadecimal (unsigned 16-bit integer) 0x0 to 0xFFFF |
| Aux Output 1 |
Output, Read-only, Analog (signed 16-bit integer) -327.67 % to 327.67 % |
| Aux Output 2 |
Output, Read-only, Analog (signed 16-bit integer) -327.67 % to 327.67 % |
| Aux Output 3 |
Output, Read-only, Analog (signed 16-bit integer) -327.67 % to 327.67 % |
| Aux Output 4 |
Output, Read-only, Analog (signed 16-bit integer) -327.67 % to 327.67 % |
| Aux Output 5 |
Output, Read-only, Analog (signed 16-bit integer) -327.67 % to 327.67 % |
| Aux Output 6 |
Output, Read-only, Analog (signed 16-bit integer) -327.67 % to 327.67 % |
| Aux Output 7 |
Output, Read-only, Analog (signed 16-bit integer) -327.67 % to 327.67 % |
| Step |
Internal Parameter, Read-only, Enumerated (signed 16-bit integer) |
| Setpoint |
Internal Parameter, Read-only, Analog (signed 16-bit integer) -327.67 % to 327.67 % |
| Output |
Output, Read-only, Analog (signed 16-bit integer) -327.67 % to 327.67 % |
| Ramp Time |
Internal Parameter, Read-only, Analog (unsigned 16-bit integer) 0 mins to 65535 mins Minimum time for the ramp to go from 0% to 100% |
| Ramp Time Extension |
Output, Read-only, Analog (unsigned 16-bit integer) 0.001 s to 65.535 s |
| Wait Time |
Internal Parameter, Read-only, Analog (unsigned 16-bit integer) 0 mins to 65535 mins |
| Wait Extension |
Output, Read-only, Analog (unsigned 16-bit integer) 0.000 s to 65.535 s |
| Program |
Internal Parameter, Read-write, Setpoint Programmer Program (Byte Array) |
| Counter Preset |
Input, Read-write, Analog (unsigned 16-bit integer) 0 to 65535 |