Ramps
Setpoint Programmer
Description (description coming soon)
Availability
  • Available only in the dw2xx & dw2xx-v2 series products
  • Requires library: Process Control (option -05)
  • Firmware versions 0x201C through 0x210D
savvy-SFD Graphic setpointProg
Graphic with Parameters setpointProg

Parameters

Reset Input, Read-write, Boolean (signed 16-bit integer)
0 = Inactive
1 = Reset
State Persistence Internal Parameter, Read-write, Boolean (signed 16-bit integer)
0 = Reset on power-up
1 = Persistent
Logic Input 1 Input, Read-write, Boolean (signed 16-bit integer)
0 = Low
1 = High
Logic Input 2 Input, Read-write, Boolean (signed 16-bit integer)
0 = Low
1 = High
Logic Input 3 Input, Read-write, Boolean (signed 16-bit integer)
0 = Low
1 = High
Logic Input 4 Input, Read-write, Boolean (signed 16-bit integer)
0 = Low
1 = High
Logic Input 5 Input, Read-write, Boolean (signed 16-bit integer)
0 = Low
1 = High
Logic Input 6 Input, Read-write, Boolean (signed 16-bit integer)
0 = Low
1 = High
Logic Input 7 Input, Read-write, Boolean (signed 16-bit integer)
0 = Low
1 = High
Parameter 1 Input, Read-write, Analog (signed 16-bit integer)
-327.67 % to 327.67 %
Parameter 2 Input, Read-write, Analog (signed 16-bit integer)
-327.67 % to 327.67 %
Parameter 3 Input, Read-write, Analog (signed 16-bit integer)
-327.67 % to 327.67 %
Parameter 4 Input, Read-write, Analog (signed 16-bit integer)
-327.67 % to 327.67 %
Parameter 5 Input, Read-write, Analog (signed 16-bit integer)
-327.67 % to 327.67 %
Parameter 6 Input, Read-write, Analog (signed 16-bit integer)
-327.67 % to 327.67 %
Parameter 7 Input, Read-write, Analog (signed 16-bit integer)
-327.67 % to 327.67 %
Counter 1 Internal Parameter, Read-only, Analog (unsigned 16-bit integer)
0 to 65535
Counter 2 Internal Parameter, Read-only, Analog (unsigned 16-bit integer)
0 to 65535
Counter 3 Internal Parameter, Read-only, Analog (unsigned 16-bit integer)
0 to 65535
Counter 4 Internal Parameter, Read-only, Analog (unsigned 16-bit integer)
0 to 65535
Aux State Output, Read-only, Hexadecimal (unsigned 16-bit integer)
0x0 to 0xFFFF
Aux Output 1 Output, Read-only, Analog (signed 16-bit integer)
-327.67 % to 327.67 %
Aux Output 2 Output, Read-only, Analog (signed 16-bit integer)
-327.67 % to 327.67 %
Aux Output 3 Output, Read-only, Analog (signed 16-bit integer)
-327.67 % to 327.67 %
Aux Output 4 Output, Read-only, Analog (signed 16-bit integer)
-327.67 % to 327.67 %
Aux Output 5 Output, Read-only, Analog (signed 16-bit integer)
-327.67 % to 327.67 %
Aux Output 6 Output, Read-only, Analog (signed 16-bit integer)
-327.67 % to 327.67 %
Aux Output 7 Output, Read-only, Analog (signed 16-bit integer)
-327.67 % to 327.67 %
Step Internal Parameter, Read-only, Enumerated (signed 16-bit integer)
Setpoint Internal Parameter, Read-only, Analog (signed 16-bit integer)
-327.67 % to 327.67 %
Output Output, Read-only, Analog (signed 16-bit integer)
-327.67 % to 327.67 %
Ramp Time Internal Parameter, Read-only, Analog (unsigned 16-bit integer)
0 mins to 65535 mins

Minimum time for the ramp to go from 0% to 100%
Ramp Time Extension Output, Read-only, Analog (unsigned 16-bit integer)
0.001 s to 65.535 s
Wait Time Internal Parameter, Read-only, Analog (unsigned 16-bit integer)
0 mins to 65535 mins
Wait Extension Output, Read-only, Analog (unsigned 16-bit integer)
0.000 s to 65.535 s
Program Internal Parameter, Read-write, Setpoint Programmer Program (Byte Array)
Counter Preset Input, Read-write, Analog (unsigned 16-bit integer)
0 to 65535