Description | Calculates the RMS (root-mean-square) value of an Analog Input. Choose the Analog Input in Input. Voltage offset is available. |
Availability |
|
savvy-SFD Graphic | |
Graphic with Parameters |
Input |
Internal Parameter, Read-write, Enumerated (signed 16-bit integer) 0 = AI1 1 = AI2 2 = AI3 3 = AI4 4 = AI5 5 = AI6 6 = AI7 7 = AI8 |
Output |
Output, Read-only, Analog (signed 16-bit integer) 0.0 % to 327.7 % |
Offset |
Input, Read-write, Analog (signed 16-bit integer) -327.67 % to 327.67 % |
Filter |
Internal Parameter, Read-write, Analog (signed 16-bit integer) 1 ms to 100 ms |