Description | While Run Enable is set to Run (1) and Preset Enable is Inactive (0), Seconds will display the time elapsed in seconds, and Minutes Elapsed will display the time elapsed in whole number of minutes. If a preset number of minutes is needed, set the value in Preset Minutes and then set Preset Enable to Active (1), and then Inactive (0). Minutes Elapsed will be set to the value of Preset Minutes. |
Availability |
|
savvy-SFD Graphic | |
Graphic with Parameters |
Minutes Elapsed |
Output, Read-only, Analog (signed 16-bit integer) 0 m to 32767 m 32767 = overflow |
Run Enable |
Input, Read-write, Boolean (signed 16-bit integer) 0 = Stop 1 = Run |
Preset Enable |
Input, Read-write, Boolean (signed 16-bit integer) 0 = Inactive 1 = Preset |
Preset Minutes |
Input, Read-write, Analog (signed 16-bit integer) 0 m to 32766 m |
Seconds |
Internal Parameter, Read-only, Analog (unsigned 16-bit integer) 0 s to 59 s |