Description | While Run Enable is set to Run (1) and Preset Enable is Inactive (0), Seconds will display the time elapsed in seconds, and Hours Elapsed will display the time elapsed in fractions of hours. If a preset number of hours is needed, set the value in Preset Hours and then set Preset Enable to Active (1), and then Inactive (0). Hours Elapsed will be set to the value of Preset Hours. |
Availability |
|
savvy-SFD Graphic | |
Graphic with Parameters |
Hours Elapsed |
Output, Read-only, Analog (signed 16-bit integer) 0 h to 32767 h 32767 = overflow |
Run Enable |
Input, Read-write, Boolean (signed 16-bit integer) 0 = Stop 1 = Run |
Preset Enable |
Input, Read-write, Boolean (signed 16-bit integer) 0 = Inactive 1 = Preset |
Preset Hours |
Input, Read-write, Analog (signed 16-bit integer) 0 h to 32766 h |
Seconds |
Internal Parameter, Read-only, Analog (unsigned 16-bit integer) 0 s to 3599 s |