Description | Diameter Calculator
|
Availability |
|
savvy-SFD Graphic | |
Graphic with Parameters |
Web Speed |
Input, Read-write, Analog (signed 16-bit integer) -105.00 % to 105.00 % |
Reel Speed |
Input, Read-write, Analog (signed 16-bit integer) -105.00 % to 105.00 % |
Absolute Web Speed |
Internal Parameter, Read-only, Analog (signed 16-bit integer) 0.00 % to 105.00 % |
Absolute Reel Speed |
Internal Parameter, Read-only, Analog (signed 16-bit integer) 0.00 % to 105.00 % |
Minimum Web Speed |
Input, Read-write, Analog (signed 16-bit integer) 0.00 % to 105.00 % |
Hold Enable |
Input, Read-write, Boolean (signed 16-bit integer) 0 = Inactive 1 = Hold |
Preset Value |
Input, Read-write, Analog (signed 16-bit integer) 0.00 % to 100.00 % |
Preset Enable |
Input, Read-write, Boolean (signed 16-bit integer) 0 = Inactive 1 = Preset |
Minimum Diameter |
Input, Read-write, Analog (signed 16-bit integer) 0.00 % to 100.00 % |
Filter Time Constant |
Input, Read-write, Analog (signed 16-bit integer) 0.00 s to 300.00 s 0 = Off |
Diameter Memory |
Internal Parameter, Read-write, Boolean (signed 16-bit integer) 0 = Not Persistent 1 = Persistent |
Diameter Output |
Output, Read-only, Analog (signed 16-bit integer) 0.00 % to 100.00 % |
Unfiltered Diameter |
Output, Read-only, Analog (signed 16-bit integer) 0.00 % to 100.00 % |
Web Break Output |
Output, Read-only, Boolean (signed 16-bit integer) 0 = OK 1 = Web Break |
Web Break Threshold |
Input, Read-write, Analog (signed 16-bit integer) 0.00 % to 100.00 % |
Web Break Enable |
Input, Read-write, Boolean (signed 16-bit integer) 0 = Disabled 1 = Enabled |