| Description | Diameter Calculator
|
| Availability |
|
| savvy-SFD Graphic | ![]() |
| Graphic with Parameters | ![]() |
| Web Speed |
Input, Read-write, Analog (signed 16-bit integer) -105.00 % to 105.00 % |
| Reel Speed |
Input, Read-write, Analog (signed 16-bit integer) -105.00 % to 105.00 % |
| Absolute Web Speed |
Internal Parameter, Read-only, Analog (signed 16-bit integer) 0.00 % to 105.00 % |
| Absolute Reel Speed |
Internal Parameter, Read-only, Analog (signed 16-bit integer) 0.00 % to 105.00 % |
| Minimum Web Speed |
Input, Read-write, Analog (signed 16-bit integer) 0.00 % to 105.00 % |
| Hold Enable |
Input, Read-write, Boolean (signed 16-bit integer) 0 = Inactive 1 = Hold |
| Preset Value |
Input, Read-write, Analog (signed 16-bit integer) 0.00 % to 100.00 % |
| Preset Enable |
Input, Read-write, Boolean (signed 16-bit integer) 0 = Inactive 1 = Preset |
| Minimum Diameter |
Input, Read-write, Analog (signed 16-bit integer) 0.00 % to 100.00 % |
| Filter Time Constant |
Input, Read-write, Analog (signed 16-bit integer) 0.00 s to 300.00 s 0 = Off |
| Diameter Memory |
Internal Parameter, Read-write, Boolean (signed 16-bit integer) 0 = Not Persistent 1 = Persistent |
| Diameter Output |
Output, Read-only, Analog (signed 16-bit integer) 0.00 % to 100.00 % |
| Unfiltered Diameter |
Output, Read-only, Analog (signed 16-bit integer) 0.00 % to 100.00 % |
| Web Break Output |
Output, Read-only, Boolean (signed 16-bit integer) 0 = OK 1 = Web Break |
| Web Break Threshold |
Input, Read-write, Analog (signed 16-bit integer) 0.00 % to 100.00 % |
| Web Break Enable |