| Description | (description coming soon) |
| Availability |
|
| savvy-SFD Graphic | ![]() |
| Graphic with Parameters | ![]() |
| Ticks |
Internal Parameter, Read-only, Analog (unsigned 32-bit integer) 0.0 ms to 858993459.0 ms |
| Nanos |
Internal Parameter, Read-only, Analog (unsigned 32-bit integer) 0 ns to 999999999 ns |
| Secs |
Internal Parameter, Read-only, Analog (unsigned 32-bit integer) 0 s to 4294967295 s |
| PTP state |
Internal Parameter, Read-only, Enumerated (signed 16-bit integer) 0 = Inactive 1 = Slave 2 = Master |
| Frequency Discipline |
Internal Parameter, Read-only, Analog (signed 16-bit integer) -140 ppm to 140 ppm |
| PTP Time Error |
Internal Parameter, Read-only, Analog (signed 64-bit integer) -5.00 µs to 5.00 µs |
| PTP Network Delay |
Internal Parameter, Read-only, Analog (unsigned 32-bit integer) 0.00 µs to 10.00 µs This is either half the measured round-trip time for standard switches, or the accurate time provided by a PTP Transparent switch. |
| Spare 1 |
Internal Parameter, Read-only, Enumerated (signed 16-bit integer) |
| Spare 2 |
Internal Parameter, Read-only, Analog (unsigned 16-bit integer) 0 to 2400 |
| Real Time Offset |
Internal Parameter, Read-only, Analog (unsigned 32-bit integer) 0 s to 1000000000 s |
| Master Serial Number |
Internal Parameter, Read-only, Serial Number (unsigned 32-bit integer) 0 = Unknown |
| Master Priority |
Internal Parameter, Read-only, Analog (signed 16-bit integer) 0 to 255 Lower numbers have higher priority 254 = Automatic (254) 255 = Incapable |
| PTP Domain |
Internal Parameter, Read-only, Analog (signed 16-bit integer) 0 to 255 0 = Error 189 = drive.web (189) |