I/O
T19 Analog Output
Description Range: +10V to -10V

Input represents the % reference of the +10 to -10V output. Monitor converts Input into the actual Volts measurement on the output terminal. Output Enable controls whether the device is putting the output Volts out to the terminal.
Availability
  • Available only in the dw2xx series products
  • Requires library: System & I/O
  • Requires: Analog and Digital I/O
  • Singleton function block
  • Firmware versions 0x2000 and later
savvy-SFD Graphic aopT19
Graphic with Parameters aopT19

Parameters

Input Input, Read-write, Analog (signed 16-bit integer)
-327.67 % to 327.67 %
Output Enable Input, Read-write, Boolean (signed 16-bit integer)
0 = Input
1 = Output
Monitor Output, Read-only, Analog (signed 16-bit integer)
-32.77 V to 32.77 V