I/O (AIO)
AI7 Digital Input
Description Range: +24V to 0V
Select the Voltage range of the input by setting Range to be 24V Logic or 5V Logic. Range defines the Voltage level that sets Output HIGH (1).
Availability
  • Available only in the dw2xx-v2 series products
  • Requires library: System & I/O
  • Requires: Eight Analog Inputs
  • Singleton function block
  • Firmware versions 0x2115 and later
savvy-SFD Graphic adin7
Graphic with Parameters adin7

Parameters

Range Internal Parameter, Read-write, Enumerated (signed 16-bit integer)
0 = 5V Logic
1 = 24V Logic
Output Output, Read-only, Boolean (signed 16-bit integer)
0 = Low
1 = High