General
On the PL-series DC Drive, several parameters are not writable via the serial communications port. This is due to internal limitations of the drive software. The affected parameters are listed below.
You should review the following list to ensure that using the serial port will not cause you problems. Note that fitting a speedy board to the drive and using Ethernet will avoid these limitations
Parameters Which Are NOT Writable via Serial Link
2) | Rated Armature Amps | 803) | Passive Rated Field Current | |
4) | Rated Field Amps | 857) | 3-Phase Field Enable | |
187) | Port 1 Baud Rate | 859) | Iarm Inst Strength | |
188) | Port 1 Function | 860) | Armature Current Commissioning Mode | |
193) | Port 1 Group ID | 865) | Adaptive Iarm Control Enable | |
194) | Port 1 Unit ID | 866) | Adaptive Iarm Discon. Gain | |
196) | Port 1 DOP3 RTS Mode | 867) | Adaptive Iarm Enable Threshold | |
199) | Fieldbus Data Control | 868) | Bridge Switch Discon. Gain | |
721) | Reduced Menu Enable | 869) | Bridge Switch Hysteresis T.C. | |
723) | Menu Language | 870) | PLL Proportional Gain In Lock | |
724) | Password | 871) | PLL Integral Gain In Lock | |
725) | Stored Password | 872) | Mains Sync Offset | |
774) | Instrument Identity | 873) | Iarm Firing Angle Backstop | |
776) | Fieldbus Output 9 GOTO | 874) | Iarm Firing Angle Pivot | |
777) | Fieldbus Output 10 GOTO | 875) | Min. Iarm Blanking Interval | |
778) | Fieldbus Output 11 GOTO | 876) | Field Firing Angle Frontstop | |
779) | Fieldbus Output 12 GOTO | 877) | Field Firing Angle Backstop | |
780) | Fieldbus Output 13 GOTO | 878) | Field Current Fbk Sample Delay | |
781) | Fieldbus Output 14 GOTO | 880) | Peak Iarm Detector Amplitude Comp. | |
782) | Fieldbus Output 15 GOTO | 881) | Peak Iarm Detector Interval Comp. | |
783) | Fieldbus Output 16 GOTO | 882) | Scan Iarm Demand Level | |
784) | 3-Button Recipe Lock Defeat | 883) | Scan T.C. | |
787) | driveweb Watchdog Timer | 884) | Bemf Calc. Iafb Ave Level | |
792) | Fieldbus Output Bit 1 GOTO | 885) | Zero Ia Inst Detector Level | |
793) | Fieldbus Output Bit 2 GOTO | 886) | Iarm Autocal Enable | |
794) | Fieldbus Output Bit 3 GOTO | 887) | Iafb Ave Zero Offset | |
795) | Fieldbus Output Bit 4 GOTO | 888) | Ia Inst Zero Offset | |
796) | Fieldbus Output Bit 5 GOTO | 889) | Iarm FeedForward Gain | |
797) | Fieldbus Output Bit 6 GOTO | 890) | AOP3 User Configured | |
798) | Fieldbus Output Bit 7 GOTO | 891) | Global Health Override | |
799) | Fieldbus Output Bit 8 GOTO | 895) | Min Display Refresh Time | |
801) | Passive Rated Armature Current |