I/O
ENC2 Speed
Description (description coming soon)
Availability
  • Available only in the dw1xx series products
  • Requires library: System & I/O
  • Requires: Encoder 2 (option -08)
  • Singleton function block
  • Firmware versions 0x100E and later
savvy-SFD Graphic enc2s
Graphic with Parameters enc2s

Parameters

Status Internal Parameter, Read-only, Enumerated (signed 16-bit integer)
0 = OK
1 = Fault on B
2 = Fault on A
3 = Fault on A and B
Pulses Per Revolution Input, Read-write, Analog (signed 16-bit integer)
1 ppr to 30000 ppr
Speed Output, Read-only, Analog (signed 16-bit integer)
-32767 RPM to 32767 RPM
Base Speed Input, Read-write, Analog (signed 16-bit integer)
-32767 RPM to 32767 RPM
Output Output, Read-only, Analog (signed 16-bit integer)
-327.67 % to 327.67 %